Search results for "Harmonic scalpel"
showing 7 items of 7 documents
A gelatin-thrombin matrix topical hemostatic agent (Floseal) in combination with harmonic scalpel is effective in patients undergoing total thyroidec…
2016
BACKGROUND: Hemostasis during thyroidectomy is essential; however, the safest, most efficient, and most cost-effective way to achieve this is unclear. This randomized, multicenter, single-blind, prospective study evaluated the efficacy and safety of using different hemostatic approaches in patients undergoing total thyroidectomy. METHODS: Patients aged ≥18 to 70 years were randomized to Floseal + a harmonic scalpel (HS), Floseal alone, HS alone, or standard total thyroidectomy. Primary endpoint was 24-hour drain output. Secondary endpoints included surgery duration and complications. RESULTS: Two hundred and six patients were randomized to Floseal + HS (n = 52), Floseal alone (n = 54), HS a…
Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial.
2004
Thyroid surgery technique has undergone very few changes in the last century. The UltraCision harmonic scalpel (UHS) (Smithfield, RI) has been widely used in laparoscopic surgery and is documented to be safe and fast for cutting and coagulating tissue. We studied whether the use of the UHS could have advantages in thyroid surgery in terms of operative time, length of hospitalization, morbidity, and general costs.Our study was a prospective randomized trial of thyroidectomies and lobectomies performed for benign thyroid diseases in an endocrine surgery unit between February 2001 and July 2002. Patients were randomized in two groups: group A (n=100) underwent thyroidectomy using UHS and group…
Is it really useful the Harmonic scalpel in axillary dissection for locally advanced breast cancer? A case series.
2017
Background. The seroma is one of the most common complications in the axillary lymph nodal dissection (different surgical approaches have been tried to reduce the seroma incidence). In our study we evaluate the outcome of patients using or not the ultrasonic scalpel (Harmonic scalpel) according to a standardized surgical technique. Patients and Methods. From January 2011 to December 2015 120 patients underwent axillary dissection for breast cancer. Patients were divided in two groups: patients belonging to the first group underwent Harmonic scalpel dissection and patients belonging to the second group underwent classical dissection. Each group consisted of 60 patients. Quadrantectomy (QUAD)…
Current status on the adoption of high energy devices in Italy. An Italian Society for Endoscopic Surgery and New Technologies (SICE) national survey
2021
Background: In the past three decades, different High Energy Devices (HED) have been introduced in surgical practice to improve the efficiency of surgical procedures. HED allow vessel sealing, coagulation and transection as well as an efficient tissue dissection. This survey was designed to verify the current status on the adoption of HED in Italy. Methods: A survey was conducted across Italian general surgery units. The questionnaire was composed of three sections (general information, elective surgery, emergency surgery) including 44 questions. Only one member per each surgery unit was allowed to complete the questionnaire. For elective procedures, the survey included questions on thyroid…
Laparotomic vs laparoscopic ovariectomy: comparing the two methods. The ovariectomy in the bitch in laparoscopic era
2015
BACKGROUND: The aim of the present work is to evaluate the effectiveness of the use of ultrasound scalpel during laparoscopic ovariectomy in the bitch. METHODS: Two groups of 10 subjects each, of different races and ages, were compared. In the first group, ovariectomy was performed laparoscopically, using harmonic scalpel to remove ovary. In the second group surgery was performed by means of classical laparotomy. RESULTS: Pre-operative time was similar in both groups. Total operative time, from incision to skin suture, showed significant difference between the two groups, being laparoscopy faster than laparotomy. Partial operative time for bilateral oophorectomy resulted lower using open te…
A case report of a difficult dissection of the iliac vessels conducted by means of the harmonic scalpel during a kidney transplantation
2011
Background. The “difficult” preparation of iliac vessels in the kidney transplant recipient caused by a perivascular fibrosis with satellite lymphadenopathy is sometimes burdened by post-transplant complications (lymphocele, seroma and hematoma). Both iliac vascular adhesions and satellite lymphoadenopaty are often due to reiterate femoral cannulation aimed to hemodialysis. Patients and Methods: The case report concerns a 60 years old female uremic patient, on dialysis for about 4 years with perivascular fibrosis and pelvic lymphadenopathy caused by bilateral femoral artery catheterization. In the course of kidney transplant, preparation of the iliac vessels was performed by ultrasonic scal…
USE OF HARMONIC SCALPEL FOR BRACHIO-BASILIC VEIN TRANSPOSITION IN AUTOGENOUS PROXIMAL ARTERIOVENOUS FISTULA
2009
Objectives: This study evaluates the effectiveness and helpfulness of ultrasonic surgical device for atraumatic surgical dissection and hemostasis in brachio-basilic vein transposition. Since prosthetic grafts have been reached poor results and high costs, the primary use of autogenous AVF is recommended. Materials and Methods: From March 2004 to March 2009 67 cases (61 F ; 6 M; mean age 52 years) of brachio-basilic arteriovenous fistulae (BBAVF) were fashioned; in second stage, after vein maturation (about 30 days), we performed a superficial transposition of arterialized basilic vein by harmonic scalpel (UltracisionTM).. Results : On 67 cases of transposition of BBAVF 2 cases failed after…